Menu

Welcome

The Finest Supporting the Bravest!

The purpose of the Fire Mechanics Section is to promote standardization of fire apparatus and equipment preventative maintenance, improve safety standards and practices, promote workshops, conferences, and seminars related to the purposes of this Section, and to promote cost savings through standardization of building and equipment purchasing and maintenance.

RECENT FIRE MECHANIC NEWS

Posted: Apr 1, 2018

Two-Inch Hose and Fire Apparatus Considerations

I don’t advocate using or not using two-inch hose for handlines.

I’ve never handled two-inch on a fireground or during a training scenario and rely on others’ expertise who are more versed in the subject as well as published pieces by people such as “water movement guru” Paul Schapiro (http://bit.ly/2F537TR). I asked Bill Graves, regional sales manager for All American Hose, to weigh in with commentary from a hose manufacturer’s perspective.

1 This Hamlin, New York, engine has two 200-foot 1¾-inch crosslays (red and yellow) and a 200-foot two-inch crosslay (blue). This rig also has two 150-foot 1¾-inch preconnects on top of the driver’s side compartment connected to a gated wye on the pump panel. (Photos 1 and 2 by Allan Smith.)

1 This Hamlin, New York, engine has two 200-foot 1¾-inch crosslays (red and yellow) and a 200-foot two-inch crosslay (blue). This rig also has two 150-foot 1¾-inch preconnects on top of the driver’s side compartment connected to a gated wye on the pump panel. (Photos 1 and 2 by Allan Smith.)

Except for a few dyed-in-the-wool traditionalists, the fire service has accepted the fact that 1¾-inch hose has replaced 1½-inch as the standard handline for initial attack. Today, using two-inch hose for initial attack is slowly gaining popularity. According to Graves, the attack hose market for 1½-inch hose accounts for 10 percent of sales, 1¾-inch has 75 percent of the sales, and two-inch has the remaining 15 percent. Generic reasons given for changing over to two-inch are lower weight, more maneuverability, less friction loss, and increased flow. If explicit firematic goals and objectives for purchasing two-inch are not clearly defined, the generalized reasons for purchasing can become false narratives.

 2 A newer engine from Hamlin has speedays with two 200-foot 1¾-inch preconnects (red and yellow) and a 200-foot two-inch preconnect (blue). All of Hamlin’s rigs have rear preconnects including 300-foot two-inch lines and preconnected portable ground monitors.

2 A newer engine from Hamlin has speedays with two 200-foot 1¾-inch preconnects (red and yellow) and a 200-foot two-inch preconnect (blue). All of Hamlin’s rigs have rear preconnects including 300-foot two-inch lines and preconnected portable ground monitors.

It is admirable when innovations and technology make firefighters’ lives easy and safer. Occasionally new concepts, designs, or changes in the fire service create skepticism and occasional ridicule. In the 1950s, firefighters ridiculed putting doors on apparatus cabs, and then they complained about going to fully enclosed four-door cabs. For years, some questioned whose idea it was to mandate using self-contained breathing apparatus. And, then it was foolish to use large-diameter hose. Adopting two-inch hose for handlines can invite similar comments from the uninformed, the uneducated, and unfortunately the ignorant.

Preplann

Read more
Posted: Apr 1, 2018

Two-Inch Hose and Fire Apparatus Considerations

I don’t advocate using or not using two-inch hose for handlines.

I’ve never handled two-inch on a fireground or during a training scenario and rely on others’ expertise who are more versed in the subject as well as published pieces by people such as “water movement guru” Paul Schapiro (http://bit.ly/2F537TR). I asked Bill Graves, regional sales manager for All American Hose, to weigh in with commentary from a hose manufacturer’s perspective.

1 This Hamlin, New York, engine has two 200-foot 1¾-inch crosslays (red and yellow) and a 200-foot two-inch crosslay (blue). This rig also has two 150-foot 1¾-inch preconnects on top of the driver’s side compartment connected to a gated wye on the pump panel. (Photos 1 and 2 by Allan Smith.)

1 This Hamlin, New York, engine has two 200-foot 1¾-inch crosslays (red and yellow) and a 200-foot two-inch crosslay (blue). This rig also has two 150-foot 1¾-inch preconnects on top of the driver’s side compartment connected to a gated wye on the pump panel. (Photos 1 and 2 by Allan Smith.)

Except for a few dyed-in-the-wool traditionalists, the fire service has accepted the fact that 1¾-inch hose has replaced 1½-inch as the standard handline for initial attack. Today, using two-inch hose for initial attack is slowly gaining popularity. According to Graves, the attack hose market for 1½-inch hose accounts for 10 percent of sales, 1¾-inch has 75 percent of the sales, and two-inch has the remaining 15 percent. Generic reasons given for changing over to two-inch are lower weight, more maneuverability, less friction loss, and increased flow. If explicit firematic goals and objectives for purchasing two-inch are not clearly defined, the generalized reasons for purchasing can become false narratives.

 2 A newer engine from Hamlin has speedays with two 200-foot 1¾-inch preconnects (red and yellow) and a 200-foot two-inch preconnect (blue). All of Hamlin’s rigs have rear preconnects including 300-foot two-inch lines and preconnected portable ground monitors.

2 A newer engine from Hamlin has speedays with two 200-foot 1¾-inch preconnects (red and yellow) and a 200-foot two-inch preconnect (blue). All of Hamlin’s rigs have rear preconnects including 300-foot two-inch lines and preconnected portable ground monitors.

It is admirable when innovations and technology make firefighters’ lives easy and safer. Occasionally new concepts, designs, or changes in the fire service create skepticism and occasional ridicule. In the 1950s, firefighters ridiculed putting doors on apparatus cabs, and then they complained about going to fully enclosed four-door cabs. For years, some questioned whose idea it was to mandate using self-contained breathing apparatus. And, then it was foolish to use large-diameter hose. Adopting two-inch hose for handlines can invite similar comments from the uninformed, the uneducated, and unfortunately the ignorant.

Preplann

Read more
Posted: Apr 1, 2018

Fire Apparatus Electric Valves: I Don’t Like Them

Editor’s Note: Every department has its own reasons for specifying certain components on its fire apparatus, including valves on a pumper. In recent years, electric valve use for intakes and discharges has increased. However, there is still a large contingent in the fire service that prefers valves with manual linkages. This month, we asked Editorial Advisory Board members Ricky Riley (left) and Bill Adams (right) to comment on electric and manual valves.

My views on electric valves are biased and outdated and do not reflect current products or trends. Some older acquaintances still in the industry and fire service have similar sentiments—so do those uneducated on the subject. Their opinions are incorporated into my narration. To temper my predisposed views, I sought input from Jason Witmier, northeast regional sales manager for Safe Fleet (representing FRC, Elkhart Brass, ROM, and FoamPro). Witmier previously worked for KME as a product manager for 14 years.

The term electric valve is a misnomer. Most valves are the same. It’s the controller that is either manually moved or activated by air, electricity, or hydraulic power (see photo). Discounting mechanical sirens and beacon rays, I dislike most electronics on fire apparatus. Manual levers, linkages, and pull-rods appear fail-safe. And when engaged, they give assurance that something is happening. Assurance is felt, heard, and seen. It can be the resistance (pressure) against a valve, the sound of water moving, or watching pressure gauge needles moving. You don’t sense that with electric valves. Besides, you can have a broken wire, a malfunctioning switch, a stuck valve, a malfunctioning visual screen, or a burned-out indicator light.

1 In the mid 1980s, the former Young Fire Apparatus delivered custom chassied pumpers with hydraulically operated valves on pump panels remotely located from the front-mounted pump. When questioned, owner Dick Young stated, “Well, we used a hydraulically operated cylinder to control each valve. It was domestically available right off the shelf. It was a double-acting cylinder with a six-inch throw. A single one-gallon oil reservoir operated all the valves; I believe it ran about 480 pounds per square inch (psi). You could put the reservoir anyplace and just run tubing to the valves. Doing so, you could locate the pump panel wherever you wanted.” Young went on to say it was an important design feature because regardless of the valve location, any size valve could be opened or closed with minimal effort, and the speed could be regulated—no matter what size valve. They never caught on. See http://bit.ly/2Fl4eg1 for more information. (Photo by Bob Milnes.)

1 In the mid 1980s, the former Young Fire Apparatus delivered custom chassied pumpers with hydraulically operated valves on pump panels remotely located from the front-mounted pump. When questioned, owner Dick Young stated, “Well, we used a hydraulically operated cylinder to control each valve. It was domestically available right off the shelf. It was a double-acting cylinder with a six-inch throw. A single one-gallon oil reservoir operated all the valves; I believe it ran about 480 pounds per square inch (psi). You could put the reservoir anyplace and ju

Read more
Posted: Apr 1, 2018

Fire Apparatus Electric Valves: I Don’t Like Them

Editor’s Note: Every department has its own reasons for specifying certain components on its fire apparatus, including valves on a pumper. In recent years, electric valve use for intakes and discharges has increased. However, there is still a large contingent in the fire service that prefers valves with manual linkages. This month, we asked Editorial Advisory Board members Ricky Riley (left) and Bill Adams (right) to comment on electric and manual valves.

My views on electric valves are biased and outdated and do not reflect current products or trends. Some older acquaintances still in the industry and fire service have similar sentiments—so do those uneducated on the subject. Their opinions are incorporated into my narration. To temper my predisposed views, I sought input from Jason Witmier, northeast regional sales manager for Safe Fleet (representing FRC, Elkhart Brass, ROM, and FoamPro). Witmier previously worked for KME as a product manager for 14 years.

The term electric valve is a misnomer. Most valves are the same. It’s the controller that is either manually moved or activated by air, electricity, or hydraulic power (see photo). Discounting mechanical sirens and beacon rays, I dislike most electronics on fire apparatus. Manual levers, linkages, and pull-rods appear fail-safe. And when engaged, they give assurance that something is happening. Assurance is felt, heard, and seen. It can be the resistance (pressure) against a valve, the sound of water moving, or watching pressure gauge needles moving. You don’t sense that with electric valves. Besides, you can have a broken wire, a malfunctioning switch, a stuck valve, a malfunctioning visual screen, or a burned-out indicator light.

1 In the mid 1980s, the former Young Fire Apparatus delivered custom chassied pumpers with hydraulically operated valves on pump panels remotely located from the front-mounted pump. When questioned, owner Dick Young stated, “Well, we used a hydraulically operated cylinder to control each valve. It was domestically available right off the shelf. It was a double-acting cylinder with a six-inch throw. A single one-gallon oil reservoir operated all the valves; I believe it ran about 480 pounds per square inch (psi). You could put the reservoir anyplace and just run tubing to the valves. Doing so, you could locate the pump panel wherever you wanted.” Young went on to say it was an important design feature because regardless of the valve location, any size valve could be opened or closed with minimal effort, and the speed could be regulated—no matter what size valve. They never caught on. See http://bit.ly/2Fl4eg1 for more information. (Photo by Bob Milnes.)

1 In the mid 1980s, the former Young Fire Apparatus delivered custom chassied pumpers with hydraulically operated valves on pump panels remotely located from the front-mounted pump. When questioned, owner Dick Young stated, “Well, we used a hydraulically operated cylinder to control each valve. It was domestically available right off the shelf. It was a double-acting cylinder with a six-inch throw. A single one-gallon oil reservoir operated all the valves; I believe it ran about 480 pounds per square inch (psi). You could put the reservoir anyplace and ju

Read more
RSS
First28322833283428352837283928402841Last

Theme picker

Upcoming Events

Theme picker

Sponsors

Fire Mechanics Section Board

Chair

Posted: Oct 21, 2015

Chair

Elliot Courage
North Whatcom Fire & Rescue
Read more

Vice Chair

Posted: Oct 21, 2015

Vice Chair

Mike Smith 
Pierce County Fire District #5
Read more

Secretary

Posted: Oct 21, 2015

Secretary

Greg Bach
South Snohomish County Fire & Rescue
Read more

Director #1

Posted: Oct 21, 2015

Director #1

Doug Jones
South Kitsap Fire & Rescue
Read more

Director #2

Posted: Oct 21, 2015

Director #2

Paul Spencer 
Fire Fleet Maintenance LLC
Read more

Director #3

Posted: Oct 21, 2015

Director #3

Jim Morris
Mountain View Fire Department
Read more

Director #4

Posted: Oct 21, 2015

Director #4

Arnie Kuchta

Clark County Fire District 6

Read more

Director #6

Posted: Oct 21, 2015

Director #6

Brett Annear
Kitsap County Fire District 18
Read more

Director #5

Posted: Oct 21, 2015

Director #5

Jay Jacks
Camano Island Fire & Rescue
Read more

Legislative Representative

Posted: Oct 21, 2015

Legislative Representative

TBD
TBD
Read more

Immediate Past Chair

Posted: Oct 20, 2015

Immediate Past Chair

Brian Fortner
Graham Fire & Rescue

Read more
RSS

Theme picker

2020 CAR SHOW