Understanding Fire Apparatus and Ambulance Standards

1711FA_HTML_020-021

 
fama forum Wesley D. Chestnut
 

Anyone involved in the emergency response service should be familiar with the standards that are promulgated by the National Fire Protection Association (NFPA).

Whether you are a firefighter, an emergency medical technician, a safety officer, a fire chief, or an emergency vehicle mechanic, NFPA standards have a significant effect on your job. What you may not realize is how simple it is for you to have an effect on the standards. Manufacturing representatives from the Fire Apparatus Manufacturers’ Association (FAMA) are involved in the development of relevant NFPA standards and encourage you to also get involved.

Apparatus- and Ambulance-Related Standards

While there are hundreds of NFPA standards, there is a subset that impacts apparatus and ambulances both in how they are designed and in how they are used. Here is the short list of standards and how each impacts emergency vehicles:

  • NFPA 1500, Standard on Fire Department Occupational Safety and Health Program: Safety guidance on the way apparatus should be used.


  • NFPA 1451, Standard for a Fire and Emergency Service Vehicle Operations Training Program: Descriptions of a training program for users of emergency vehicles. Annex B is a complete list of vehicle-related hazards that should be trained on.


  • NFPA 1901, Standard for Automotive Fire Apparatus: Performance standard and equipment list for fire apparatus.


  • NFPA 1906, Standard for Wildland Fire Apparatus: Performance standard and equipment list for wildland fire apparatus.


  • NFPA 1911, Standard for the Inspection, Maintenance, Testing, and Retirement of In-Service Emergency Vehicles: Detailed lists of items that should be inspected and tested on in-service emergency service vehicles.


  • NFPA 1912, Standard for Fire Apparatus Refurbishing: Items that should be included in a refurbishment.


  • NFPA 1917, Standard for Automotive Ambulances: Performance standard and equipment list for ambulances.


  • NFPA 1962, Standard for the Care, Use, Inspection, Service Testing, and Replacement of Fire Hose, Couplings, Nozzles, and Fire Hose Appliances: Includes the safe means of testing fire hose using an apparatus pump.


Process Overview

With each standard produced by the NFPA, there is an assigned technical committee. The technical committee is typically made up of 30 members with one-third being users, one-third from enforcers or other interest groups, and one-third from manufacturers. Members are volunteers and pay their own travel expenses. Each committee reviews input from the public and casts votes on the proposed language. If the technical committee rejects or alters the language from the original input, it must provide a reason. Once the technical committee vot

Read more
Posted: Nov 9, 2017

PL Custom Builds Custom EMS Rig for Princeton, New Jersey

 
special Delivery Alan M. Petrillo
 
Alan M. Petrillo

The Princeton (NJ) First Aid & Rescue Squad wanted a custom ambulance that it could station at Princeton University during the school year and turned to PL Custom Emergency Vehicles to build the rig.

Frank Setnicky, director of the Princeton First Aid & Rescue Squad, says the Squad provides ambulance and rescue services to the 18 square miles of the borough of Princeton with a population of about 30,000 residents that doubles when Princeton University is in session. “We wanted a pretty straightforward ambulance without a lot of bells and whistles but with some customized design features,” Setnicky says. “This new rig was going to be stationed on the Princeton University campus during school classes.”

1 The Princeton (NJ) First Aid & Rescue Squad went to PL Custom Emergency Vehicles for a new custom ambulance on a 2017 Ford E-450 chassis with an all-aluminum modular body. (Photos courtesy of PL Custom Emergency Vehicles.)

1 The Princeton (NJ) First Aid & Rescue Squad went to PL Custom Emergency Vehicles for a new custom ambulance on a 2017 Ford E-450 chassis with an all-aluminum modular body. (Photos courtesy of PL Custom Emergency Vehicles.)

Chad Newsome, national sales manager for P.L. Custom Body and Equipment Co., Inc., parent company of PL Custom Emergency Vehicles, says Princeton had taken the design of its then current ambulances and worked with him to develop the design it wanted on a new rig. “It went through a request for proposal (RFP) process and solicited information from several vendors,” Newsome points out. “Then Princeton whittled the proposals down to its most recent vehicle provider and us. We got the contract.”

Custom Configurations

Newsome notes that PL Custom installed a combination 12-volt/110-volt heating and air-conditioning (HVAC) system in the Princeton ambulance because the rig would be stored outside at Princeton University during the school year and would need to be plugged into shore power when on site. PL Custom installed dual shore lines on the ambulance, one each side—the first for standard charging and the other for charging the HVAC system.

2 The PL Custom ambulance for Princeton has all Whelen LED warning, scene, compartment, interior, and underbody lighting along with a Whelen Howler siren.

2 The PL Custom ambulance for Princeton has all Whelen LED warning, scene, compartment, interior, and underbody lighting along with a Whelen Howler siren.

“The Princeton Squad also wanted a custom configuration on the body itself,” Newsome says. “Of the five exterior storage compartments, only one of them was a standard compartment. The driver’s side rear compartment was ¾ high with double doors, and the passenger side forward was a full-height compartment.”

Custom features also include pushbutt

Read more
Posted: Nov 9, 2017

PL Custom Builds Custom EMS Rig for Princeton, New Jersey

 
special Delivery Alan M. Petrillo
 
Alan M. Petrillo

The Princeton (NJ) First Aid & Rescue Squad wanted a custom ambulance that it could station at Princeton University during the school year and turned to PL Custom Emergency Vehicles to build the rig.

Frank Setnicky, director of the Princeton First Aid & Rescue Squad, says the Squad provides ambulance and rescue services to the 18 square miles of the borough of Princeton with a population of about 30,000 residents that doubles when Princeton University is in session. “We wanted a pretty straightforward ambulance without a lot of bells and whistles but with some customized design features,” Setnicky says. “This new rig was going to be stationed on the Princeton University campus during school classes.”

1 The Princeton (NJ) First Aid & Rescue Squad went to PL Custom Emergency Vehicles for a new custom ambulance on a 2017 Ford E-450 chassis with an all-aluminum modular body. (Photos courtesy of PL Custom Emergency Vehicles.)

1 The Princeton (NJ) First Aid & Rescue Squad went to PL Custom Emergency Vehicles for a new custom ambulance on a 2017 Ford E-450 chassis with an all-aluminum modular body. (Photos courtesy of PL Custom Emergency Vehicles.)

Chad Newsome, national sales manager for P.L. Custom Body and Equipment Co., Inc., parent company of PL Custom Emergency Vehicles, says Princeton had taken the design of its then current ambulances and worked with him to develop the design it wanted on a new rig. “It went through a request for proposal (RFP) process and solicited information from several vendors,” Newsome points out. “Then Princeton whittled the proposals down to its most recent vehicle provider and us. We got the contract.”

Custom Configurations

Newsome notes that PL Custom installed a combination 12-volt/110-volt heating and air-conditioning (HVAC) system in the Princeton ambulance because the rig would be stored outside at Princeton University during the school year and would need to be plugged into shore power when on site. PL Custom installed dual shore lines on the ambulance, one each side—the first for standard charging and the other for charging the HVAC system.

2 The PL Custom ambulance for Princeton has all Whelen LED warning, scene, compartment, interior, and underbody lighting along with a Whelen Howler siren.

2 The PL Custom ambulance for Princeton has all Whelen LED warning, scene, compartment, interior, and underbody lighting along with a Whelen Howler siren.

“The Princeton Squad also wanted a custom configuration on the body itself,” Newsome says. “Of the five exterior storage compartments, only one of them was a standard compartment. The driver’s side rear compartment was ¾ high with double doors, and the passenger side forward was a full-height compartment.”

Custom features also include pushbutt

Read more
Posted: Nov 9, 2017

PL Custom Builds Custom EMS Rig for Princeton, New Jersey

 
special Delivery Alan M. Petrillo
 
Alan M. Petrillo

The Princeton (NJ) First Aid & Rescue Squad wanted a custom ambulance that it could station at Princeton University during the school year and turned to PL Custom Emergency Vehicles to build the rig.

Frank Setnicky, director of the Princeton First Aid & Rescue Squad, says the Squad provides ambulance and rescue services to the 18 square miles of the borough of Princeton with a population of about 30,000 residents that doubles when Princeton University is in session. “We wanted a pretty straightforward ambulance without a lot of bells and whistles but with some customized design features,” Setnicky says. “This new rig was going to be stationed on the Princeton University campus during school classes.”

1 The Princeton (NJ) First Aid & Rescue Squad went to PL Custom Emergency Vehicles for a new custom ambulance on a 2017 Ford E-450 chassis with an all-aluminum modular body. (Photos courtesy of PL Custom Emergency Vehicles.)

1 The Princeton (NJ) First Aid & Rescue Squad went to PL Custom Emergency Vehicles for a new custom ambulance on a 2017 Ford E-450 chassis with an all-aluminum modular body. (Photos courtesy of PL Custom Emergency Vehicles.)

Chad Newsome, national sales manager for P.L. Custom Body and Equipment Co., Inc., parent company of PL Custom Emergency Vehicles, says Princeton had taken the design of its then current ambulances and worked with him to develop the design it wanted on a new rig. “It went through a request for proposal (RFP) process and solicited information from several vendors,” Newsome points out. “Then Princeton whittled the proposals down to its most recent vehicle provider and us. We got the contract.”

Custom Configurations

Newsome notes that PL Custom installed a combination 12-volt/110-volt heating and air-conditioning (HVAC) system in the Princeton ambulance because the rig would be stored outside at Princeton University during the school year and would need to be plugged into shore power when on site. PL Custom installed dual shore lines on the ambulance, one each side—the first for standard charging and the other for charging the HVAC system.

2 The PL Custom ambulance for Princeton has all Whelen LED warning, scene, compartment, interior, and underbody lighting along with a Whelen Howler siren.

2 The PL Custom ambulance for Princeton has all Whelen LED warning, scene, compartment, interior, and underbody lighting along with a Whelen Howler siren.

“The Princeton Squad also wanted a custom configuration on the body itself,” Newsome says. “Of the five exterior storage compartments, only one of them was a standard compartment. The driver’s side rear compartment was ¾ high with double doors, and the passenger side forward was a full-height compartment.”

Custom features also include pushbutt

Read more
Posted: Nov 9, 2017

Modernizing Fire Apparatus Pump Panels with Flow Meters

 

Today, most fire department pumpers feature only pounds-per-square-inch (psi) gauges to monitor each discharge outlet.

Although using these psi gauges in conjunction with calculating friction loss within a particular hose layout has been common in the fire service for many years, it is time for the fire service to seriously consider integrating flow meters into each of its discharge outlets to create a safer, more efficient, and more effective fireground.

To look at the benefits of adding flow meters to our discharge outlets, let’s take a moment to review the principle characteristics of a workable nozzle and the difficulties in verifying if a nozzle is receiving proper pressure and flow rate using only psi gauges.

Table 1: Nozzle Characteristics for Smooth Bore Nozzles
Table 2: Effects of Operating Nozzles at 10 psi Above and Below the 50-psi Mark
Table 3: Effects of Overpressurizing a 15⁄16-Inch Smooth Bore Nozzle

Optimal Nozzle Characteristics

Like many tools, a nozzle has an optimal point of performance. This optimal point typically reflects research and hands-on training performed by departments to find nozzle characteristics that work within their department. Some common nozzle characteristics that your department may focus on are as follows:

  • Target flow rate.


  • Reasonable nozzle reaction.


  • Fire stream quality.


  • Horizontal reach of the fire stream.


Fire departments will balance the positives and negatives of each nozzle characteristic and will generally publish, through a department policy or training program, the optimal point to operate a particular nozzle. For example, a department may choose to operate all 1¾-inch handlines with 15⁄16-inch smooth bore nozzles flowing 185 gallons per minute (gpm) at 50 psi, creating 69 pounds of force (lbf) of nozzle reaction and 59 feet of horizontal reach.

1 Commonly fire department pumpers have included psi gauges and push/pull “T” handles to monitor and control the flow to hoselines. (Photos by author.)

1 Commonly fire department pumpers have included psi gauges and push/pull “T” handles to monitor and control the flow to hoselines. (Photos by author.)

From this point, it is important to understand that the farther away a nozzle operates from the department-established optimal point, the less efficient and effective the nozzle becomes for the nozzle team to operate. Table 1 highlights some of the pitfalls associated with smooth bore nozzles operating above or below their optimal points. As shown, operating below the optimal point can endanger the nozzle team with a fire stream that does not have an adequate flow rate. Equally troubling is an overpressured nozzle that will have increased nozzle reaction, causing additional work, fatigue, and even possible safety concerns.

To bring in specific values to highlight the previous point, Table 2 shows

Read more
RSS